Overview
-> It always makes a self-diagnosis with inner circuit and it prevent the troubles beforehand.
-> It is easy to make an optical axis with 5-point level meter.
Laser type Distance Sensor
Max. detecting distance, 20m!
2 pcs of optional distance can be set!
Distance measurement sensor, working with its reflector
By phase difference between the benchmark projected optical signal and the received optical signal from the reflector, the distance between 2 points will be calculated.
Output can be set at any distance of its detectable range.
This equipment is composed of the amplifier unit and the reflector. It detects when crane or AGV etc. is close. It
measures the distance between the unit and the reflector with phase-difference and executes output. Trouble output (FAULT) executes when light-emitting amount or light- receiving amount is getting lower or troubled.
Model No. | KAD-200 | |
Power source | AC100V to 240V(+15%, -10%, 50/60Hz) | |
Power consumption | 10VA or less when 100VAC, 15VA or less when 200VAC | |
Detecting distance | 0.4 to 20m | |
Detectable objects | Reflector (RRP-KAD01) | |
Directional angle | ±2.5° | |
Output | Control output(OUT1,2) | 1C relay(250VAC 3A, cosφ=1) Relay isn`t excited and LED lights up when within setting distance |
Trouble output(FAULT) | 1C relay(250VAC 3A, cosφ=1) Relay isn`t excited and LED lights up or flickers when light-emitting/receving amount is getting lower or troubled | |
Analog output | It output distance data/light-receiving amount*1 with analog value. (Don`t use it except for adjustment) | |
Absolute precision/ repeatability | ±400mm, ±200mm | |
Resolution | 80mm | |
Hysteresis | 500mm | |
Response time | 50msec or less*2 | |
Connection | M4 screw terminal(15 pins) | |
Ambient illuminance | 10,000lx or less(Halogen and mercury light), 6,000lx(incandescent lamp: Max.illuminance) | |
Ambient temperature/humidity | -10 degrees C to +55 degrees C, 85%RH or less(not condensing, not icing) | |
Vibration resistance | Double amplitude 1.5mm, 10 to 55Hz, each 2 hour in X, Y and Z directions | |
Impact resistance | 490m/s2(50G) each 10 time for X, Y and Z direction | |
Case materials | Steel plate(SPCC) | |
Impact resistance | Approx.3kg |
*1 Changeover by mode setting switch(T side : light-receiving amount analog output, R side : Distance analog output)
*2 Don`t operate during 2sec after putting power source on.
Terminal No. | 1-2 | 2-3 | 4-5 | 5-6 | |
Power-OFF state | OPEN | CLOSE | OPEN | CLOSE | |
Power-ON state | Within setting distance | OPEN | CLOSE | OPEN | CLOSE |
Over setting distance | CLOSE | OPEN | CLOSE | OPEN |
Trouble output(FAULT)
Terminal No. | 9-10 | 10-11 | |
Power-OFF state | OPEN | CLOSE | |
Power-ON state | When normal | CLOSE | OPEN |
When troubled | OPEN | CLOSE |
Hokuyo chuyên sản xuất các thiết bị quang học như máy đo khoảng cách laser, thiết bị truyền dữ liệu quang học, cảm biến ảnh, bộ đếm tự động và cửa tự động mang lại hiệu suất và độ tin cậy cao.