Model No. | Amplifier : Basic type LAV-10P/Strong power type LAV-11P(Projector), LAV-10A(Receiver) Sensor head : FHM-211-1 or FHM-311 Fiber unit*1 : FHV-321(2m), FHV-351(5m), FHV-411(10m) |
Safety standard | Class 1(JIS C6802) |
Detectable objects | Steel material with φ100mm or more(FHM-311) |
Detecting distance | 50m(Detection margin : 10,000 times or more at 10m*2) |
Power source | 100 to 240VAC(+10%, – 15%, 50/60Hz) |
Power consumption | Projector : 5VA or less, Receiver : 5.5VA or less |
Control output | 1C relay contact(250VAC 3A, 30VDC 5A, COSφ=1), Photo-coupler(120V, 100mA) |
Warning output |
Light-emitting amount Lowering output |
Analog voltage output | DC voltage output in proportion to light-receiving amount(Saturated value 9V or more but do not use it except for adjustment) |
Response time | Contact output : 40msec or less, transistor output : 30msec or less |
Operating mode | Changeover of DARK-ON/LIGHT-ON |
Connection | Connector type(Cable 2m) |
Fiber unit characteristics | Allowable bending radius : 100mm, Max. pressure : 784MPa, Tension strength : 490N |
Ambient illuminance | Incandescent lamp : 10,000lux |
Ambient temperature | Amplifier : -10 to +55°, Sensor head/Fiber unit : -10 to +200° |
Ambient humidity | 45 to 85%RH(Not frozen) |
Insulation resistance | 20MΩ or more(1,000V megger between power/output contact and case) |
Withstand voltage | 1,500VAC/min. (Between power/output contact and case) |
Vibration resistance | 10 to 55Hz Double amplitude 1.5mm Each 2 hour in X, Y and Z directions |
Impact resistance | 490m/s2, Each 3 time in X, Y and Z directions |
Protective structure | Amplifier : IP64(IEC standard) Sensor head : IP66(IEC standard) Fiber unit : Corrugated tube with blade(SUS) |
Case | Amplifier : Aluminum die-casting, Sensor head : Aluminum |
Weight | Amplifier : Approx. 950g Sensor head : FHM-211-1 approx. 1.5kg, FHM-311 approx. 4.0kg, Fiber unit : FHV-321 approx. 1.0kg, FHV-351 approx. 1.8kg, FHV-411 approx. 2.8kg |